Ukuze sikunike lula kwaye andise ishishini lethu, sikwanabo nabahloli kwiQela leQC kwaye siqinisekise ngenkonzo yethu ilungileyo kunye nemveliso ye-ODM Manufacturer Hot Selling Vet Diagnostic Device Clinical Auto Hematology Analyzer for Veterinary Use, Inkqubo yethu ekhethekileyo ngokwenene iphelisa ukusilela kwecandelo. kwaye inika abathengi bethu umgangatho ophezulu ongaguqukiyo, osivumela ukuba silawule iindleko, sicwangcise umthamo kunye nokugcina ukuhanjiswa kwexesha.
Ukuze sikunikeze lula kwaye andise ishishini lethu, sikwanabo nabahloli kwiQela leQC kwaye sikuqinisekisa ngenkonzo yethu engcono kunye nemveliso yethu.I-Hematology Analyzer kunye ne-Auto Hematology Analyzer, Inkampani yethu ithathela ingqalelo ukuba ukuthengisa ayikokufumana inzuzo kuphela kodwa kukwandise inkcubeko yenkampani yethu kwihlabathi.Ke besisebenza nzima ukukubonelela ngenkonzo yentliziyo iphela kwaye sizimisele ukukubonisa elona xabiso likhuphisanayo kwimarike.
I-AerC-3 Auto Hematology Analyzer sisixhobo sovavanyo lweklinikhi esinemisebenzi etyebileyo kunye nokusebenza ngokulula.Inokubonelela ngeeparamitha ezingama-21 kunye ne-3 histograms.Ukubalwa kwetshaneli kabini.Ngexesha lenkqubo yokuhlalutya isampuli, ukususwa kokuvala ngokuzenzekelayo kunye nokubala kwakhona ngokuzenzekelayo kuqinisekisa iziphumo zovavanyo ezichanekileyo nezizinzileyo.Isetyenziswa kakhulu kwiilebhu zesibhedlele, amasebe eklinikhi kunye namaziko ophando.
Iiparamitha | Ukuchaneka | Qhubeka uye ngaphaya | Uluhlu lweLinearity | |
Uluhlu | CV | |||
WBC | (7.0 ~ 15.0)*109/L | ≦2.0% | ≦0.5% | (0.0~99.9)*109/L |
(4.0~6.9)*109/L | ≦3.5% | |||
RBC | (3.50~6.5)*109/L | ≦1.5% | ≦0.5% | (0.0~7)*1012/L |
HGB | (100 ~ 180) g/L | ≦1.5% | ≦0.5% | (0.0 ~ 240) g/L |
HGT | (70.0 ~ 110.0) fL | ≦1.5% | / | (0.0~250.0)fL |
PLT | (150.0~500.0)*109/L | ≦4.0% | ≦1% | (0.0~999.0)*109/L |
(100.0 ~ 149.0)*109/L | ≦5.0% |
1.Iiparamitha ezithuthukisiweyo
- Iiparamitha ezingama-21, ii-Histograms ezi-3
- Ukhetho olunokwenzeka lweeyunithi zeparameter, Iilwimi ezininzi ziyafumaneka
2.I-alam ye-histogram engaqhelekanga
- Ukuba i-histogram yesiphumo sohlalutyo lwesampulu ayiqhelekanga.Umatshini uya kwenza ngokuzenzekelayo i-alam ye-histogram.Yazisa i-R1, i-R2, i-R3, i-R4, i-Rm, i-Pm ngokohlobo olukhethekileyo
3.Ukuchaneka okuphezulu
- Ukubalwa kwetshaneli kabini, akukho ukungcoliseka phakathi kwamajelo kunye nezinga eliphantsi lokuthwala
- Ukulungelelanisa ngokuzenzekelayo amandla ombane e-HGB engenanto, Lungisa ngokuzenzekelayo imida ye-alam yokuvala kunye neqamza lokubala imingxuma
4.Ukusebenza kakuhle kweendleko
- 2 reagent: Diluent kunye Lyse
- Ukusetyenziswa kwe-reagent ephantsi
- I-lyse eyakhelwe-ngaphakathi, ukusetyenziswa kwendawo ephezulu
5.Ukubala kwakhona okuzenzekelayo
- Ukubala kwakhona ngokuzenzekelayo emva kokuvula unyango ngelixa umngxuma wokubala uvalekile, kunqanda ukubala kwakhona igazi
6.Uyilo lokhuseleko
- Ukwahlula kwesekethe kunye nolwelo, ukukhuselwa kokhuseleko
- Ulondolozo olulula
7.Block-ukucoca
- Gxila kwaye uhlambe emva naphambili.ixesha lokwenyani esweni umsebenzi wokutshisa uxinzelelo oluphezulu kunye nokucima ibhloko ngokuzenzekelayo
Ukuze sikunike lula kwaye andise ishishini lethu, sikwanabo nabahloli kwiQela leQC kwaye siqinisekise ngenkonzo yethu ilungileyo kunye nemveliso ye-ODM Manufacturer Hot Selling Vet Diagnostic Device Clinical Auto Hematology Analyzer for Veterinary Use, Inkqubo yethu ekhethekileyo ngokwenene iphelisa ukusilela kwecandelo. kwaye inika abathengi bethu umgangatho ophezulu ongaguqukiyo, osivumela ukuba silawule iindleko, sicwangcise umthamo kunye nokugcina ukuhanjiswa kwexesha.
ODM ManufacturerI-Hematology Analyzer kunye ne-Auto Hematology Analyzer, Inkampani yethu ithathela ingqalelo ukuba ukuthengisa ayikokufumana inzuzo kuphela kodwa kukwandise inkcubeko yenkampani yethu kwihlabathi.Ke besisebenza nzima ukukubonelela ngenkonzo yentliziyo iphela kwaye sizimisele ukukubonisa elona xabiso likhuphisanayo kwimarike.